| Advantage Reliability Services |
Vibration Analysis Samples |
Vibration Analysis Example #2 |
| |
 |
|
|
| The bottom spectrum shows a pump that was misaligned and had a worn coupling element. The top spectrum shows the same pump after it was precision aligned during a scheduled maintenance shutdown. |
|
| |
|
Vibration Analysis, Preventive Maintenance, and Thermography. |
| |
|
|